• No results found

5

Outdoor model

Indoor units number Piping total length Connecting pipe length

Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function

Capacity [Rated (Min.-Max.) Hz]

Dehumidification Outdoor air flow Breaker capacity Running current Power input Power factor Starting current

Compressor motor current Fan motor current

Model Output Winding

resistance (at 20 °C) Model

Winding

resistance (at 20 °C) Dimensions W x H x D Weight

Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity (R410A) Refrigeration oil (Model)

m m m m kW /h m3 /h

A A W

% A A A

W Ω

Ω mm

kg dB rpm kg cc Compressor 2 Electrical dataFan motorSpecial remarksCapacitySystem

Coefficient of performance(C.O.P) 2 Outdoor unit power supply

MXZ-2A30VA Single phase 230 V, 50 Hz

2 Max. 20 Max. 15 Refer to 9 Refer to 9

10

90 3.60

0.2 KNB092FEDH KNB073FGDH

750 U-V 1.70 V-W 1.70 W-U 1.70

RC0J50-CF BLK-WHT 14.2 WHT-RED 14.2 RED-BLK 14.2

800 x 550 x 285 34

2 1.15 320 (NEO22) Cooling

3.0 (1.1 - 4.0) — 1,950

2.87 595

2.67 5.04

46/44 850/650

Heating 4.0 (1.0 - 4.5)

— 1,950

3.6 745

3.40 5.37

47/46 850/650

E1 E2

TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C

OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)

•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.

1 Measured under rated operating frequency.

2 Electrical data is for only outdoor unit.

3 These specifications are when all indoor units are operating.

Outdoor model

Indoor units number Piping total length Connecting pipe length

Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function

Capacity [Rated (Min.-Max.) Hz]

Dehumidification Outdoor air flow Breaker capacity Running current Power input Power factor Starting current

Compressor motor current Fan motor current Model

Output Winding

resistance(at 20 °C) Model

Winding

resistance(at 20 °C) Dimensions W x H x D Weight

Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity(R410A) Refrigeration oil (Model)

m m m m kW /h m3 /h

A A W

% A A A

W Ω

Ω mm

kg dB rpm

kg cc Compressor 2 Electrical dataFan motorSpecial remarksCapacitySystem

Coefficient of performance(C.O.P) 2

MXZ-2A40VA - Single phase 230 V, 50 Hz

2 Max. 30 Max. 20 Refer to 9 Refer to 9

15

95 4.78

0.2 SNB130FKCH

1,100 U-V 0.64 V-W 0.64 W-U 0.64

RC0J50-CF BLK-WHT 14.2 WHT-RED 14.2 RED-BLK 14.2

800 x 550 x 285 40

2 1.3 450 (NEO22)

Heating 4.5 (1.0 - 5.0)

— 1,860

4.32 945

4.12 4.76

48/47 850/490

MXZ-2A40VA - Single phase 230 V, 50 Hz

2 Max. 30 Max. 20 Refer to 9 Refer to 9

15

95 4.78

0.2 KNB092FEDH

1,100 U-V 1.70 V-W 1.70 W-U 1.70

RC0J50-CF BLK-WHT 14.2 WHT-RED 14.2 RED-BLK 14.2

800 x 550 x 285 34

2 1.15 320 (NEO22) Cooling

4.0 (1.1 - 4.5)

— 1,950

4.78 1,045

4.58 3.83

47/44 850/650

Heating 4.5 (1.0 - 5.0)

— 1,950

4.32 945

4.12 4.76

48/47 850/650 Cooling

4.0 (1.1 - 4.5)

— 1,860

4.78 1,045

4.58 3.83

47/44 850/530

E1 E2

Outdoor unit power supply

TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C

OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)

•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.

1 Measured under rated operating frequency.

2 Electrical data is for only outdoor unit.

3 These specifications are when all indoor units are operating.

Outdoor model

Indoor units number Piping total length Connecting pipe length

Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function

Capacity [Rated (Min.-Max.) Hz]

Dehumidification Outdoor air flow Breaker capacity Running current Power input Power factor Starting current

Compressor motor current Fan motor current

Model

Output Winding

resistance(at 20 °C) Model

Winding

resistance(at 20 °C) Dimensions W x H x D Weight

Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity(R410A) Refrigeration oil (Model)

MXZ-2A52VA Single phase 230 V, 50 Hz

2 Max. 30 Max. 20 Refer to 9 Refer to 9

15

97 7.64

0.2

1,400 U-V 0.64 V-W 0.64 W-U 0.64

RC0J50-CF BLK-WHT 14.2 WHT-RED 14.2 RED-BLK 14.2

800 x 550 x 285 40

2 1.3 450 (NEO22) Cooling

5.2 (1.1 - 6.0)

— 1,860

6.75 1,505

6.55 3.46

49/45 850/530

Heating 6.4 (1.0 - 7.2)

— 1,860

7.64 1,705

7.44 3.75

50/48 850/490

U-V 0.45 V-W 0.45 W-U 0.45

U-V 0.98 V-W 0.98 W-U 0.98 m

m m m kW /h m3 /h

A A W

% A A A

W Ω

Ω mm

kg dB rpm

kg cc Compressor 2 Electrical dataFan motorSpecial remarksCapacitySystem

Coefficient of performance(C.O.P) 2 Outdoor unit power supply

MXZ-3A54VA Single phase 230 V, 50 Hz

2 to 3 Max. 50 Max. 25 Refer to 9 Refer to 9

25

99 6.39

0.2

1,400

RC0J60-AA BLK-WHT 15.2 WHT-RED 15.2 RED-BLK 15.2

840 x 710 x 330 57

2 2.7

600 (NEO22) 700 (NEO22)

Cooling 5.4 (2.9-6.8)

— 2,525

5.69 1,295

5.49 4.17

46/44 650/510

Heating 6.8 (2.6-9.0)

— 2,470

6.39 1,455

6.19 4.67

48/47 640/510 SNB130FLDH1 SNB130FLEH1 SNB130FGBH1 SNB130FGBH1T SNB130FKCH

SNB130FKMH

E1

E2

E2 E1

E3

E2

E1 E3

E2

E1 E3

,

, , , ,

E5 E4, ,E6,E7

E5 E4, ,E6,E7

E7 E5 E4, ,E6

TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C

OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)

•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.

1 Measured under rated operating frequency.

2 Electrical data is for only outdoor unit.

3 These specifications are when all indoor units are operating.

MXZ-4A71VA Single phase 230 V, 50 Hz

2 to 4 Max. 60 Max. 25 Refer to 9 Refer to 9

25

99 8.56

0.2

2,000

RC0J60-AA BLK-WHT 15.2 WHT-RED 15.2 RED-BLK 15.2

840 x 710 x 330 58

2 2.7

600 (NEO22) 700 (NEO22) Heating 8.6 (3.4-9.0)

— 2,790

8.56 1,950

8.36 4.41

50/48 700/510 SNB130FLDH1 SNB130FLEH1 SNB130FGBH1 SNB130FGBH1T Outdoor model

Indoor units number Piping total length Connecting pipe length

Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function

Capacity [Rated (Min.-Max.) Hz]

Dehumidification Outdoor air flow Breaker capacity Running current Power input Power factor Starting current

Compressor motor current Fan motor current

Model

Output Winding

resistance (at 20 °C) Model

Winding

resistance (at 20°C) Dimensions W x H x D Weight

Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity (R410A) Refrigeration oil (Model)

m m m m kW /h m3 /h

A A W

% A A A

W Ω

Ω mm

kg dB rpm

kg cc Compressor 2 Electrical dataFan motorSpecial remarksCapacitySystem

Coefficient of performance(C.O.P) 2

MXZ-4A80VA Single phase 230 V, 50 Hz

2 to 4 Max. 70 Max. 25 Refer to 9 Refer to 9

25

99 9.62

0.2

TNB220FMCH

2,100 U-V 1.41 V-W 1.41 W-U 1.41

PM8H60-UA BLK-WHT 15.2 WHT-RED 15.2 RED-BLK 15.2

900 x 900 x 320 70 67

2 3.5 870 (NEO22) Cooling

8.0 (3.7-9.2)

— 2,530

9.62 2,190

9.42 3.65

46/44 560/400

Heating 9.4 (3.4-11.6)

— 2,630

8.48 1,930

8.28 4.87

48/46 590/400 U-V 0.45

V-W 0.45 W-U 0.45 U-V 0.98 V-W 0.98 W-U 0.98 Outdoor unit power supply

Cooling 7.1 (3.7-8.8)

— 2,525

8.48 1,930

8.28 3.68

48/45 650/510

, ,

E1 , E2 E3

E2

E1 E3

E2 E1, ,E3

E7 E5 E4, ,E6

E1 E2

E5 E4, ,E6,E7

E5 E4, ,E6,E7

TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C

OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)

•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.

1 Measured under rated operating frequency.

2 Electrical data is for only outdoor unit.

3 These specifications are when all indoor units are operating.

Outdoor model

Indoor units number Piping total length Connecting pipe length

Height difference (Indoor ~ Outdoor) Height difference (Indoor ~ Indoor) Function

Capacity [Rated (Min.-Max.) Hz Dehumidification

Outdoor air flow Breaker capacity Running current Power input Power factor Starting current

Compressor motor current Fan motor current Model

Output Winding

resistance(at 20 °C) Model

Winding

resistance(at 20 °C) Dimensions W x H x D Weight

Sound level (High/Low) Fan speed (High/Low) Fan speed regulator Refrigerant filling capacity(R410A) Refrigeration oil (Model)

m m m m kW /h m3 /h

A A W

% A A A

W Ω

Ω mm

kg dB rpm kg cc Compressor 2 Electrical dataFan motorSpecial remarksCapacitySystem

Coefficient of performance(C.O.P) 2 Outdoor unit power supply

MXZ-5A100VA Single phase 230 V, 50 Hz

2 to 5 Max. 80 Max. 25 Refer to 9 Refer to 9

25

99 12.88

0.2 TNB220FMCH

2,700 U-V 1.41 V-W 1.41 W-U 1.41

PM8H60-UA BLK-WHT 15.2 WHT-RED 15.2 RED-BLK 15.2

900 x 900 x 320 68

2 4.0 870 (NEO22) Cooling

10 (3.7 - 11)

— 3,396 12.88 2,935

12.68 3.41

51/45 700/500

Heating 12 (3.4 - 14)

— 3,558 12.45 2,835

12.25 4.23

54/46 700/500

TEST CONDITIONS COOLING INDOOR Dry-bulb temperature 27.0°C Wet-bulb temperature 19.0°C OUTDOOR Dry-bulb temperature 35.0°C Wet-bulb temperature 24.0°C HEATING INDOOR Dry-bulb temperature 20.0°C

OUTDOOR Dry-bulb temperature 7.0°C Wet-bulb temperature 6.0°C NOTE: •Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)

•Refer to 3 “INDOOR/OUTDOOR CORRESPONDENCE TABLE” for the combination.

1 Measured under rated operating frequency.

2 Electrical data is for only outdoor unit.

3 These specifications are when all indoor units are operating.

In document 3. INDOOR/OUTDOOR CORRESPONDENCE TABLE ··· 10 (сторінка 61-66)