7] Standard Operation Data (Reference Data)
1. Single unit (1) Cooling operation
Operation Outdoor unit model
PUHY-P200YJM-A PUHY-P250YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C 27°C/ 19°C
[81°F/ 66°F] [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ] 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
2 3
No. of units in opera-
tion 2 3
Model - 100/100 100/100/50
Piping
Main pipe
m [ ft ]
5 [17] 5 [17]
Branch pipe 10 [33] 10 [33]
Total pipe length 25 [82] 35 [115]
Fan speed - Hi Hi
Amount of refrigerant kg
[ lbs-oz ] 11.0 [24] 12.6 [28]
Outdoor unit
Electric current A 9.0 11.8
Voltage V 400 400
Compressor frequency Hz 52 65
LEV open- ing
Indoor unit
Pulse
325/325 325/325/362
SC (LEV1) 80 100
LEV2 - -
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.77/ 0.74 3.11/ 0.86
[402/ 107] [451/ 125]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
89 [192] 85 [185]
Heat exchanger out-
let (TH3) 44 [111] 44 [111]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 22 [72] 24 [75]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 47 [117] 38 [100]
Indoor unit
LEV inlet 22 [72] 24 [75]
Heat exchanger
outlet 6 [43] 6 [43]
- 122 -
HWE10040 GB
Operation Outdoor unit model
PUHY-P300YJM-A PUHY-P350YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C 27°C/ 19°C
[81°F/ 66°F] [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ] 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
3 4
No. of units in opera-
tion 3 4
Model - 100/100/100 100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17] 5 [17]
Branch pipe 10 [33] 10 [33]
Total pipe length 35 [115] 45 [148]
Fan speed - Hi Hi
Amount of refrigerant kg
[ lbs-oz ] 14.0 [31] 17.6 [39]
Outdoor unit
Electric current A 14.4 17.6
Voltage V 400 400
Compressor frequency Hz 74 95
LEV open- ing
Indoor unit
Pulse
325/325/325 325/325/325/362
SC (LEV1) 100 100
LEV2 - -
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.95/ 0.84 2.86/ 0.76
[428/ 122] [415/ 110]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
84 [183] 90 [194]
Heat exchanger out-
let (TH3) 44 [111] 43 [109]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 22 [72] 22 [72]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 42 [108] 42 [108]
Indoor unit
LEV inlet 22 [72] 22 [72]
Heat exchanger
outlet 6 [43] 6 [43]
Operation Outdoor unit model
PUHY-P400YJM-A PUHY-P450YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C 27°C/ 19°C
[81°F/ 66°F] [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ] 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
4 5
No. of units in opera-
tion 4 5
Model - 100/100/100/100 100/100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17] 5 [17]
Branch pipe 10 [33] 10 [33]
Total pipe length 45 [148] 55 [181]
Fan speed - Hi Hi
Amount of refrigerant kg
[ lbs-oz ] 19.0 [42] 19.4 [43]
Outdoor unit
Electric current A 21.0 24.8
Voltage V 400 400
Compressor frequency Hz 97 111
LEV open- ing
Indoor unit
Pulse
325/325/325/325 325/325/325/325/362
SC (LEV1) 190 190
LEV2 - -
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
3.05/ 0.84 3.07/ 0.79
[442/ 122] [445/ 115]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 85 [185]
Heat exchanger out-
let (TH3) 45 [113] 48 [118]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 25 [77] 28 [82]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 38 [100] 40 [104]
Indoor unit
LEV inlet 25 [77] 28 [82]
Heat exchanger
outlet 4 [39] 4 [39]
- 124 -
HWE10040 GB
(2) Heating operation
Operation Outdoor unit model
PUHY-P200YJM-A PUHY-P250YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ] 20°C/- [68°F/- ]
Outdoor 7°C/ 6°C 7°C/ 6°C
[45°F/ 43°F] [45°F/ 43°F]
Indoor unit
No. of connected units
Unit
2 3
No. of units in opera-
tion 2 3
Model - 100/100 100/100/50
Piping
Main pipe
m [ ft ]
5 [17] 5 [17]
Branch pipe 10 [33] 10 [33]
Total pipe length 25 [82] 35 [115]
Fan speed - Hi Hi
Amount of refrigerant kg
[ lbs-oz ] 11.0 [24] 12.6 [28]
Outdoor unit
Electric current A 9.3 11.7
Voltage V 400 400
Compressor frequency Hz 53 71
LEV open- ing
Indoor unit
Pulse
332/332 332/332/373
SC (LEV1) 0 0
LEV2 - -
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.81/ 0.66 2.85/ 0.61
[408/ 96] [413/ 88]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 82 [180]
Heat exchanger inlet
(TH3) 0 [32] 0 [32]
Accumulator inlet -2 [28] -2 [28]
Accumulator outlet -2 [28] -2 [28]
Compressor inlet -2 [28] -2 [28]
Compressor shell
bottom 40 [104] 40 [104]
Indoor unit
LEV inlet 37 [99] 38 [100]
Heat exchanger
inlet 80 [176] 80 [176]
Operation Outdoor unit model
PUHY-P300YJM-A PUHY-P350YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ] 20°C/- [68°F/- ]
Outdoor 7°C/ 6°C 7°C/ 6°C
[45°F/ 43°F] [45°F/ 43°F]
Indoor unit
No. of connected units
Unit
3 4
No. of units in opera-
tion 3 4
Model - 100/100/100 100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17] 5 [17]
Branch pipe 10 [33] 10 [33]
Total pipe length 35 [115] 45 [148]
Fan speed - Hi Hi
Amount of refrigerant kg
[ lbs-oz ] 14.0 [31] 17.6 [39]
Outdoor unit
Electric current A 14.8 17.9
Voltage V 400 400
Compressor frequency Hz 81 101
LEV open- ing
Indoor unit
Pulse
332/332/332 332/332/332/373
SC (LEV1) 0 0
LEV2 - -
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.78/ 0.61 2.81/ 0.57
[403/ 88] [408/ 83]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 82 [180]
Heat exchanger inlet
(TH3) -1 [30] -1 [30]
Accumulator inlet -3 [27] -3 [27]
Accumulator outlet -3 [27] -3 [27]
Compressor inlet -3 [27] -3 [27]
Compressor shell
bottom 40 [104] 40 [104]
Indoor unit
LEV inlet 39 [102] 39 [102]
Heat exchanger
inlet 80 [176] 80 [176]
- 126 -
HWE10040 GB
Operation Outdoor unit model
PUHY-P400YJM-A PUHY-P450YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ] 20°C/- [68°F/- ]
Outdoor 7°C/ 6°C 7°C/ 6°C
[45°F/ 43°F] [45°F/ 43°F]
Indoor unit
No. of connected units
Unit
4 5
No. of units in opera-
tion 4 5
Model - 100/100/100/100 100/100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17] 5 [17]
Branch pipe 10 [33] 10 [33]
Total pipe length 45 [148] 55 [181]
Fan speed - Hi Hi
Amount of refrigerant kg
[ lbs-oz ] 19.0 [42] 19.4 [43]
Outdoor unit
Electric current A 20.5 23.4
Voltage V 400 400
Compressor frequency Hz 102 117
LEV open- ing
Indoor unit
Pulse
332/332/332/332 332/332/332/332/373
SC (LEV1) 0 0
LEV2 - -
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.74 / 0.61 2.81/ 0.61
[397/ 88] [408/ 88]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
89 [192] 89 [192]
Heat exchanger inlet
(TH3) -1 [30] -1 [30]
Accumulator inlet -3 [27] -3 [27]
Accumulator outlet -3 [27] -3 [27]
Compressor inlet -3 [27] -3 [27]
Compressor shell
bottom 40 [104] 40 [104]
Indoor unit
LEV inlet 37 [99] 37 [99]
Heat exchanger
inlet 87 [189] 87 [189]
2. 2-unit combination (1) Cooling operation
Operation
Outdoor unit model PUHY-P500YSJM-A
PUHY-P250YJM-A PUHY-P250YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
5 No. of units in opera-
tion 5
Model - 100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 55 [181]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 25.1 [55]
Outdoor unit
Electric current A 24.6
Voltage V 400
Compressor frequency Hz 65 65
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325
SC (LEV1) 100 100
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
3.11/ 0.86 3.11/ 0.86
[451/ 125] [451/ 125]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
85 [185] 85 [185]
Heat exchanger out-
let (TH3) 47 [117] 47 [117]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 27 [81] 27 [81]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 38 [100] 38 [100]
Indoor unit
LEV inlet 27 [81]
Heat exchanger
outlet 6 [43]
- 128 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P500YSJM-A1
PUHY-P200YJM-A PUHY-P300YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
5 No. of units in opera-
tion 5
Model - 100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 55 [181]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 23.6 [52]
Outdoor unit
Electric current A 24.1
Voltage V 400
Compressor frequency Hz 52 74
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325
SC (LEV1) 80 105
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.77/ 0.74 2.86/ 0.69
[402/ 107] [415/ 100]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
89 [192] 90 [194]
Heat exchanger out-
let (TH3) 44 [111] 43 [109]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 22 [72] 24 [75]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 47 [117] 48 [118]
Indoor unit
LEV inlet 24 [75]
Heat exchanger
outlet 6 [43]
Operation
Outdoor unit model PUHY-P550YSJM-A
PUHY-P250YJM-A PUHY-P300YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
6 No. of units in opera-
tion 6
Model - 100/100/100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 65 [214]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 25.5 [56]
Outdoor unit
Electric current A 27.5
Voltage V 400
Compressor frequency Hz 65 71
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/362
SC (LEV1) 159 237
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
3.10/ 0.78 3.10/ 0.74
[450/ 113] [450/ 107]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
91 [196] 89 [192]
Heat exchanger out-
let (TH3) 47 [117] 47 [117]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 27 [81] 27 [81]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 42 [108] 42 [108]
Indoor unit
LEV inlet 27 [81]
Heat exchanger
outlet 6 [43]
- 130 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P600YSJM-A
PUHY-P250YJM-A PUHY-P350YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
6 No. of units in opera-
tion 6
Model - 100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 65 [214]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 29.0 [64]
Outdoor unit
Electric current A 30.0
Voltage V 400
Compressor frequency Hz 65 92
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325
SC (LEV1) 159 237
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
3.10/ 0.74 3.10/ 0.78
[450/ 107] [450/ 113]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
91 [196] 91 [196]
Heat exchanger out-
let (TH3) 47 [117] 47 [117]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 27 [81] 27 [81]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 42 [108] 42 [108]
Indoor unit
LEV inlet 27 [81]
Heat exchanger
outlet 6 [43]
Operation
Outdoor unit model PUHY-P600YSJM-A1
PUHY-P300YJM-A PUHY-P300YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
6 No. of units in opera-
tion 6
Model - 100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 65 [214]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 25.5 [56]
Outdoor unit
Electric current A 30.4
Voltage V 400
Compressor frequency Hz 74 74
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325
SC (LEV1) 105 105
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.86/ 0.69 2.86/ 0.69
[415/ 100] [415/ 100]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
90 [194] 90 [194]
Heat exchanger out-
let (TH3) 43 [109] 43 [109]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 24 [75] 24 [75]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 48 [118] 48 [118]
Indoor unit
LEV inlet 24 [75]
Heat exchanger
outlet 6 [43]
- 132 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P650YSJM-A
PUHY-P300YJM-A PUHY-P350YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
7 No. of units in opera-
tion 7
Model - 100/100/100/100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 75 [247]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 30.6 [67]
Outdoor unit
Electric current A 32.7
Voltage V 400
Compressor frequency Hz 74 95
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325/362
SC (LEV1) 105 105
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.86/ 0.69 2.86/ 0.69
[415/ 100] [415/ 100]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
90 [194] 90 [194]
Heat exchanger out-
let (TH3) 43 [109] 43 [109]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 24 [75] 24 [75]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 48 [118] 48 [118]
Indoor unit
LEV inlet 24 [75]
Heat exchanger
outlet 6 [43]
Operation
Outdoor unit model PUHY-P700YSJM-A
PUHY-P350YJM-A PUHY-P350YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
7 No. of units in opera-
tion 7
Model - 100/100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 75 [247]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 36.0 [79]
Outdoor unit
Electric current A 36.0
Voltage V 400
Compressor frequency Hz 95 95
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325/325
SC (LEV1) 105 105
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.86/ 0.69 2.86/ 0.69
[415/ 100] [415/ 100]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
90 [194] 90 [194]
Heat exchanger out-
let (TH3) 43 [109] 43 [109]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 24 [75] 24 [75]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 48 [118] 48 [118]
Indoor unit
LEV inlet 24 [75]
Heat exchanger
outlet 6 [43]
- 134 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P700YSJM-A1
PUHY-P300YJM-A PUHY-P400YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
7 No. of units in opera-
tion 7
Model - 100/100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 75 [247]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 32.5 [72]
Outdoor unit
Electric current A 36.9
Voltage V 400
Compressor frequency Hz 74 97
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325/325
SC (LEV1) 105 185
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.86/ 0.69 2.86/ 0.76
[415/ 100] [415/ 110]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
90 [194] 95 [203]
Heat exchanger out-
let (TH3) 43 [109] 46 [115]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 24 [75] 24 [75]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 48 [118] 47 [117]
Indoor unit
LEV inlet 24 [75]
Heat exchanger
outlet 6 [43]
Operation
Outdoor unit model PUHY-P750YSJM-A
PUHY-P350YJM-A PUHY-P400YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
8 No. of units in opera-
tion 8
Model - 100/100/100/100/100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 85 [279]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 36.7 [81]
Outdoor unit
Electric current A 39.6
Voltage V 400
Compressor frequency Hz 95 97
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325/325/362
SC (LEV1) 141 185
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.95/ 0.81 2.86/ 0.76
[428/ 117] [415/ 110]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
96 [205] 95 [203]
Heat exchanger out-
let (TH3) 47 [117] 46 [115]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 25 [77] 24 [75]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 56 [133] 47 [117]
Indoor unit
LEV inlet 25 [77]
Heat exchanger
outlet 4 [39]
- 136 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P800YSJM-A
PUHY-P350YJM-A PUHY-P450YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
8 No. of units in opera-
tion 8
Model - 100/100/100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 85 [279]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 37.0 [82]
Outdoor unit
Electric current A 43.4
Voltage V 400
Compressor frequency Hz 95 111
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325/325/325
SC (LEV1) 141 185
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.95/ 0.81 2.86/ 0.76
[428/ 117] [415/ 110]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
96 [205] 95 [203]
Heat exchanger out-
let (TH3) 47 [117] 46 [115]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 25 [77] 24 [75]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 56 [133] 47 [117]
Indoor unit
LEV inlet 25 [77]
Heat exchanger
outlet 4 [39]
Operation
Outdoor unit model PUHY-P800YSJM-A1
PUHY-P400YJM-A PUHY-P400YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
8 No. of units in opera-
tion 8
Model - 100/100/100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 85 [279]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 36.7 [81]
Outdoor unit
Electric current A 43.0
Voltage V 400
Compressor frequency Hz 97 97
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325/325/325
SC (LEV1) 185 185
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.86/ 0.76 2.86/ 0.76
[415/ 110] [415/ 110]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
95 [203] 95 [203]
Heat exchanger out-
let (TH3) 46 [115] 46 [115]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 24 [75] 24 [75]
Compressor inlet 19 [66] 19 [66]
Compressor shell
bottom 47 [117] 47 [117]
Indoor unit
LEV inlet 24 [75]
Heat exchanger
outlet 4 [39]
- 138 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P850YSJM-A
PUHY-P400YJM-A PUHY-P450YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
9 No. of units in opera-
tion 9
Model - 100/100/100/100/100/100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 95 [312]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 37.5 [83]
Outdoor unit
Electric current A 47.5
Voltage V 400
Compressor frequency Hz 97 111
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325/325/325/362
SC (LEV1) 171 171
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
3.12/ 0.83 3.12/ 0.83
[453/ 120] [453/ 120]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
98 [208] 98 [208]
Heat exchanger out-
let (TH3) 47 [117] 47 [117]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 26 [79] 26 [79]
Compressor inlet 20 [68] 20 [68]
Compressor shell
bottom 47 [117] 47 [117]
Indoor unit
LEV inlet 26 [79]
Heat exchanger
outlet 4 [39]
Operation
Outdoor unit model PUHY-P900YSJM-A
PUHY-P450YJM-A PUHY-P450YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
27°C/ 19°C [81°F/ 66°F]
Outdoor 35°C/- [95°F/- ]
Indoor unit
No. of connected units
Unit
9 No. of units in opera-
tion 9
Model - 100/100/100/100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 95 [312]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 39.8 [88]
Outdoor unit
Electric current A 51.4
Voltage V 400
Compressor frequency Hz 111 111
LEV open- ing
Indoor unit
Pulse
325/325/325/325/325/325/325/325/325
SC (LEV1) 171 171
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
3.12/ 0.83 3.12/ 0.83
[453/ 120] [453/ 120]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
98 [208] 98 [208]
Heat exchanger out-
let (TH3) 47 [117] 47 [117]
Accumulator inlet 7 [45] 7 [45]
Accumulator outlet 7 [45] 7 [45]
SCC outlet (TH6) 26 [79] 26 [79]
Compressor inlet 20 [68] 20 [68]
Compressor shell
bottom 47 [117] 47 [117]
Indoor unit
LEV inlet 26 [79]
Heat exchanger
outlet 4 [39]
- 140 -
HWE10040 GB
(2) Heating operation
Operation
Outdoor unit model PUHY-P500YSJM-A
PUHY-P250YJM-A PUHY-P250YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ]
Outdoor 7°C/ 6°C
[45°F/ 43°F]
Indoor unit
No. of connected units
Unit
5 No. of units in opera-
tion 5
Model - 100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 55 [181]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 25.1 [55]
Outdoor unit
Electric current A 24.1
Voltage V 400
Compressor frequency Hz 71 71
LEV open- ing
Indoor unit
Pulse
332/332/332/332/332
SC (LEV1) 0
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.85/ 0.61 2.85/ 0.61
[413/ 88] [413/ 88]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 82 [180]
Heat exchanger inlet
(TH3) 0 [32] 0 [32]
Accumulator inlet -2 [28] -2 [28]
Accumulator outlet -2 [28] -2 [28]
Compressor inlet -2 [28] -2 [28]
Compressor shell
bottom 40 [104] 40 [104]
Indoor unit
LEV inlet 37 [99]
Heat exchanger
inlet 80 [176]
Operation
Outdoor unit model PUHY-P500YSJM-A1
PUHY-P200YJM-A PUHY-P300YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ]
Outdoor 7°C/ 6°C
[45°F/ 43°F]
Indoor unit
No. of connected units
Unit
5 No. of units in opera-
tion 5
Model - 100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 55 [181]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 23.6 [52]
Outdoor unit
Electric current A 24.8
Voltage V 400
Compressor frequency Hz 53 81
LEV open- ing
Indoor unit
Pulse
332/332/332/332/332
SC (LEV1) 0 0
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.81/ 0.66 2.59/ 0.57
[408/ 96] [376/ 83]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 82 [180]
Heat exchanger inlet
(TH3) 0 [32] 0 [32]
Accumulator inlet -2 [28] -2 [28]
Accumulator outlet -2 [28] -2 [28]
Compressor inlet -2 [28] -2 [28]
Compressor shell
bottom 40 [104] 22 [72]
Indoor unit
LEV inlet 37 [99]
Heat exchanger
inlet 80 [176]
- 142 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P550YSJM-A
PUHY-P250YJM-A PUHY-P300YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ]
Outdoor 7°C/ 6°C
[45°F/ 43°F]
Indoor unit
No. of connected units
Unit
6 No. of units in opera-
tion 6
Model - 100/100/100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 65 [214]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 25.5 [56]
Outdoor unit
Electric current A 27.0
Voltage V 400
Compressor frequency Hz 71 79
LEV open- ing
Indoor unit
Pulse
332/332/332/332/332/373
SC (LEV1) 0
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.61/ 0.61 2.68/ 0.57
[379/ 88] [389/ 83]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 83 [181]
Heat exchanger inlet
(TH3) 0 [32] 0 [32]
Accumulator inlet -2 [28] -2 [28]
Accumulator outlet -2 [28] -2 [28]
Compressor inlet -2 [28] -2 [28]
Compressor shell
bottom 30 [86] 34 [93]
Indoor unit
LEV inlet 35 [95]
Heat exchanger
inlet 80 [176]
Operation
Outdoor unit model PUHY-P600YSJM-A
PUHY-P250YJM-A PUHY-P350YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ]
Outdoor 7°C/ 6°C
[45°F/ 43°F]
Indoor unit
No. of connected units
Unit
6 No. of units in opera-
tion 6
Model - 100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 65 [214]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 29.0 [64]
Outdoor unit
Electric current A 30.2
Voltage V 400
Compressor frequency Hz 71 99
LEV open- ing
Indoor unit
Pulse
332/332/332/332/332/332
SC (LEV1) 0
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.61/ 0.61 2.76/ 0.57
[379/ 88] [400/ 83]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 86 [187]
Heat exchanger inlet
(TH3) 0 [32] 0 [32]
Accumulator inlet -2 [28] -2 [28]
Accumulator outlet -2 [28] -2 [28]
Compressor inlet -2 [28] -2 [28]
Compressor shell
bottom 30 [86] 34 [93]
Indoor unit
LEV inlet 35 [95]
Heat exchanger
inlet 82 [180]
- 144 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P600YSJM-A1
PUHY-P300YJM-A PUHY-P300YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ]
Outdoor 7°C/ 6°C
[45°F/ 43°F]
Indoor unit
No. of connected units
Unit
6 No. of units in opera-
tion 6
Model - 100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 65 [214]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 25.5 [56]
Outdoor unit
Electric current A 30.8
Voltage V 400
Compressor frequency Hz 81 81
LEV open- ing
Indoor unit
Pulse
332/332/332/332/332/332
SC (LEV1) 0 0
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.59/ 0.57 2.59/ 0.57
[376/ 83] [376/ 83]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 82 [180]
Heat exchanger inlet
(TH3) 0 [32] 0 [32]
Accumulator inlet -2 [28] -2 [28]
Accumulator outlet -2 [28] -2 [28]
Compressor inlet -2 [28] -2 [28]
Compressor shell
bottom 22 [72] 22 [72]
Indoor unit
LEV inlet 35 [95]
Heat exchanger
inlet 80 [176]
Operation
Outdoor unit model PUHY-P650YSJM-A
PUHY-P300YJM-A PUHY-P350YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ]
Outdoor 7°C/ 6°C
[45°F/ 43°F]
Indoor unit
No. of connected units
Unit
7 No. of units in opera-
tion 7
Model - 100/100/100/100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 75 [247]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 30.6 [67]
Outdoor unit
Electric current A 32.8
Voltage V 400
Compressor frequency Hz 81 101
LEV open- ing
Indoor unit
Pulse
332/332/332/332/332/332/373
SC (LEV1) 0
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.59/ 0.57 2.59/ 0.57
[376/ 83] [376/ 83]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 82 [180]
Heat exchanger inlet
(TH3) 0 [32] 0 [32]
Accumulator inlet -2 [28] -2 [28]
Accumulator outlet -2 [28] -2 [28]
Compressor inlet -2 [28] -2 [28]
Compressor shell
bottom 22 [72] 22 [72]
Indoor unit
LEV inlet 35 [95]
Heat exchanger
inlet 80 [176]
- 146 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P700YSJM-A
PUHY-P350YJM-A PUHY-P350YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ]
Outdoor 7°C/ 6°C
[45°F/ 43°F]
Indoor unit
No. of connected units
Unit
7 No. of units in opera-
tion 7
Model - 100/100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 75 [247]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 36.0 [79]
Outdoor unit
Electric current A 35.7
Voltage V 400
Compressor frequency Hz 101 101
LEV open- ing
Indoor unit
Pulse
332/332/332/332/332/332/332
SC (LEV1) 0
LEV2 2100 2100
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.59/ 0.57 2.59/ 0.57
[376/ 83] [376/ 83]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 82 [180]
Heat exchanger inlet
(TH3) 0 [32] 0 [32]
Accumulator inlet -2 [28] -2 [28]
Accumulator outlet -2 [28] -2 [28]
Compressor inlet -2 [28] -2 [28]
Compressor shell
bottom 22 [72] 22 [72]
Indoor unit
LEV inlet 35 [95]
Heat exchanger
inlet 80 [176]
Operation
Outdoor unit model PUHY-P700YSJM-A1
PUHY-P300YJM-A PUHY-P400YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ]
Outdoor 7°C/ 6°C
[45°F/ 43°F]
Indoor unit
No. of connected units
Unit
7 No. of units in opera-
tion 7
Model - 100/100/100/100/100/100/100
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 75 [247]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 32.5 [72]
Outdoor unit
Electric current A 37.0
Voltage V 400
Compressor frequency Hz 81 102
LEV open- ing
Indoor unit
Pulse
332/332/332/332/332/332/332
SC (LEV1) 0 0
LEV2 2100 1920
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.59/ 0.57 2.91/ 0.60
[376/ 83] [422/ 87]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 89 [192]
Heat exchanger inlet
(TH3) 0 [32] -2 [28]
Accumulator inlet -2 [28] -4 [25]
Accumulator outlet -2 [28] -4 [25]
Compressor inlet -2 [28] -4 [25]
Compressor shell
bottom 22 [72] 40 [104]
Indoor unit
LEV inlet 35 [95]
Heat exchanger
inlet 83 [181]
- 148 -
HWE10040 GB
Operation
Outdoor unit model PUHY-P750YSJM-A
PUHY-P350YJM-A PUHY-P400YJM-A
Operating conditions
Ambient tempera- ture
Indoor
DB/WB
20°C/- [68°F/- ]
Outdoor 7°C/ 6°C
[45°F/ 43°F]
Indoor unit
No. of connected units
Unit
8 No. of units in opera-
tion 8
Model - 100/100/100/100/100/100/100/50
Piping
Main pipe
m [ ft ]
5 [17]
Branch pipe 10 [33]
Total pipe length 85 [279]
Fan speed - Hi
Amount of refrigerant kg
[ lbs-oz ] 36.7 [81]
Outdoor unit
Electric current A 39.5
Voltage V 400
Compressor frequency Hz 101 102
LEV open- ing
Indoor unit
Pulse
332/332/332/332/332/332/332/373
SC (LEV1) 0
LEV2 1740 1920
Pressure High pressure (after O/S)/low
pressure (before accumulator) MPa [ psi ]
2.90/ 0.62 2.91/ 0.60
[421/ 90] [422/ 87]
Temp. of each sec- tion
Outdoor unit
Discharge (TH4)
°C [ °F ]
82 [180] 89 [192]
Heat exchanger inlet
(TH3) -1 [30] -2 [28]
Accumulator inlet -3 [27] -4 [25]
Accumulator outlet -3 [27] -4 [25]
Compressor inlet -3 [27] -4 [25]
Compressor shell
bottom 30 [86] 40 [104]
Indoor unit
LEV inlet 39 [102]
Heat exchanger
inlet 83 [181]