12. Installation Instruction

12.2 Indoor Unit

12.2.1 How to Fix Installation Plate

The mounting wall shall be strong and solid enough to prevent it from vibration.

3 4

5 6

Wall Wall Wall

Installation plate1 2 screw

More than More than

Indoor unit

128 mm

241.5 mm

128 mm More

than

For best strength of INDOOR unit installation, it is highly recommended to locate “ ” at 5 position as shown.

Measuring Tape

1 1

2

Model Dimension

     

HZ9***, AZ9***

HZ12***

or

490 mm 82 mm 435 mm 435 mm 127 mm 88 mm

The center of installation plate should be at more than  at right and left of the wall.

The distance from installation plate edge to ceiling should more than .

From installation plate center to unit’s left side is .

From installation plate center to unit’s right side is .

B : For left side piping, piping connection for liquid should be about  from this line.

: For left side piping, piping connection for gas should be about  from this line.

1 Mount the installation plate on the wall with 5 screws or more (at least 5 screws).

(If mounting the unit on the concrete wall, consider using anchor bolts.)

o Always mount the installation plate horizontally by aligning the marking-off line with the thread and using a level gauge.

2 Drill the piping plate hole with ø70 mm hole-core drill.

o Line according to the left and right side of the installation plate. The meeting point of the extended line is the center of the hole. Another method is by putting measuring tape at position as shown in the diagram above. The hole center is obtained by measuring the distance namely 128 mm for left and right hole respectively.

o Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor side.

12.2.2 To Drill a Hole in the Wall and Install a Sleeve of Piping

1 Insert the piping sleeve to the hole.

2 Fix the bushing to the sleeve.

3 Cut the sleeve until it extrudes about 15 mm from the wall.

CAUTION

When the wall is hollow, please be sure to use the sleeve for tube assembly to prevent dangers caused by mice biting the connection cable.

4 Finish by sealing the sleeve with putty or caulking compound at the final stage.

15 mm

Putty or caulking compound ø70 mm through hole

Indoor Outdoor

Sleeve for tube assembly

Wall

Approx. 5 - 7 mm

Bushing for tube assembly

12.2.3 Indoor Unit Installation

Do not turn over the unit without it’s shock absorber during pull out the piping. It may cause intake grille damage.

Use shock absorber during pull out the piping to protect the intake grille from damage.

PUSH PUSH

Piping

Intake grille pull outthepiping

PUSH PUSH

Piping

Shock absorber pull out thepiping

12.2.3.1 For the right rear piping

Pull out the Indoor piping Install the Indoor Unit Secure the Indoor Unit Insert the connection cable

12.2.3.2 For the right and right bottom piping

Pull out the Indoor piping Install the Indoor Unit Insert the connection cable Secure the Indoor Unit

12.2.3.3 For the embedded piping

Replace the drain hose

Bend the embedded piping

Pull the connection cable into Indoor Unit

Cut the embedded piping

Install the Indoor Unit

Connect the piping

Insulate and finish the piping

Secure the Indoor Unit

Use a spring bender or equivalent to bend the piping so that the piping is not crushed.

The inside and outside connection cable can be connected without removing the front grille.

When determining the dimensions of the piping, slide the unit all the way to the left on the installation plate.

Please refer to “Insulation of piping connection” column as mentioned in indoor/outdoor unit installation.

Please refer to “Connecting the piping” column in outdoor unit section. (Below steps are done after connecting the outdoor piping and gas-leakage confirmation).

Cover for piping In case of the cover is cut, keep

the cover at the rear of chassis as shown in the illust ration for future reinstallation .

(Left, right and 2 bottom covers for piping.)

How to keep the cover

Guide

surface Connection cable About

70 – 8 0 mm

Connection cable Gas side piping Liquid side piping Drain hose

Insert the connection cable

To take out the unit, pus h th e ma rking at th e bottom unit, and pull it slightly towards you to disengage the hooks from the unit.

g n i k r a m

Install the indoor unit Hook the indoor unit onto the upper portion of installation plate. (Engage the indoor unit with the upper edge of the installation plate). Ensure the hooks are prope rly seate d on the installation plate by moving it in left and right.

Drain hose Sleeve for piping hole

Indoor unit

Hooks at installation plate

Piping

1. Press the lower left and right side of the unit against the installation plate until hooks engages with their slot (sound cli ck).

Secure the Indoor Unit

Installation plate Unit’s

hook Cover for the bottom piping Tape it with piping in a

position as mentioned in Fig. bel ow.

Cover for the right piping Piping

Drain hose

Cover for the left piping

Right and Right Bottom piping Right Rear piping

Cover for the bottom piping Cover for the

bottom piping Tape it with

piping in a position as mentioned in

Fig. bel ow.

Cover for the right piping

Piping

Drain hose

Cover for the left piping

Rear view for left piping installation

Drain cap Drain hose

• How to pull the piping and drain hose out, in case of the embedded piping.

PVC tube for drain hose

Indoor unit 100 mm

Piping Cable Apply putty or

caulking material to seal the wall

opening. Connection

cable Piping

Morethan

470 m m Mo re t han

950 mm

PVC tube (VP-65)for piping and connection cable

PVC tubefor drain hose (VP-30) PVC tube for

drain hose (VP-20) Mo re tha n 70 0 mm

• In case of left piping how to insert the connection cable and drain hose.

Drain hose from main unit

Cable 45°

Drain hose

Piping

(For the right piping, follow the same procedure)

Sleeve for piping hole Drain hose

Piping

Connection cable More than 950 mm Replace the drain hose

12.2.4 Connect the Cable to the Indoor Unit

1. The inside and outside connection cable can be connected without removing the front grille.

2. Decide on the type of power supply connection to be used, indoor power supply or outdoor power supply.

12.2.4.1 In case of indoor power supply

3. Install the indoor unit on the installing holder that mounted on the wall.

4. Open the front panel and grille door by loosening the screw.

5. Cable connection to the power supply through Isolating Devices (Disconnecting means).

 Connect approved type polychloroprene sheathed power supply cord 3 × 1.5mm

2

type designation 60245 IEC 57 or heavier cord to the terminal board, and connect the others end of the cord to Isolating Devices (Disconnecting means).

 Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, or otherwise) is too short.

 In unavoidable case, joining of power supply cord between isolating devices and terminal board of air conditioner shall be done by using approved socket and plug with earth pin rated 16A. Wiring work to both socket and plug must follow to national wiring standard.

6. Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement.

7. Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5 mm

2

flexible cord, type designation 60245 IEC 57 or heavier cord. Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or otherwise) is too short. Allowable connection cable length of each indoor unit shall be 30 mm or less.

8. Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right escapement.

9. Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoor unit according to the diagram below.

Terminals on the outdoor unit Colour of wires (connection cable) Terminals on the indoor unit

Terminals on the isolating devices (Disconnecting means)

(Power supply cord)

L N 1 2 3

(L) (N)

1 2 3

L N

Recommended length (mm)

Tape

Connection cable Tape

Power supply cord

Terminal Board

Control Board Earth wire longer than others AC wires for safety reason Holder Holder

Indoor & outdoor connection cable Isolating

Devices Outdoor unit Power supply

cord Recommended

length (mm)

55 35 35 50 40 35 60

a

b d e

f g

c

6 8

b c d e f g a

10. Secure the power supply cord and connection cable onto the control board with the holder.

11. Close grille door by tighten with screw and close the front panel.

12.2.4.2 In case of outdoor power supply

3. Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed 4 × 1.5 mm

2

flexible cord, type designation 60245 IEC 57 or heavier cord. Do not use joint connection cable. Replace the wire if the existing wire (from concealed wiring, or otherwise) is too short. Allowable connection cable length of each indoor unit shall be 30 mm or less.

4. Bind all the indoor and outdoor connection cable with tape and route the connection cable via the right escapement.

5. Remove the tapes and connect the connection cable between indoor unit and outdoor unit according to the diagram below.

Terminals on the outdoor unit Colour of wires (connection cable) Terminals on the indoor unit Terminals on the isolating devices

(Disconnecting means) (Power supply cord)

L N 1 2 3

(L) (N)

1 2 3

L N

Tape

Connection cable Terminal

Board

Control Board Earth wire longer than others AC wires for safety reason Holder

Indoor & outdoor connection cable

Outdoor unit

a b

d

Recommended

c

length (mm)

Recommended length (mm)

a b c d 50 40 35 60

4

6. Secure the connection cable onto the control board with the holder.

 Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor’s respectively.

 Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.

12.2.4.3 Wire Stripping, Connecting Requirement

Wire stripping

5 mm or more

Conductor over inserted

No loose strand when inserted

Indoor/outdoor connection terminal board

10 ± 1 mm

Conductor fully inserted

Conductor not fully inserted

(gap between wires) ACCEPT PROHIBITED PROHIBITED

WARNING

RISK OF FIRE JOINING OF WIRES MAY

CAUSE OVERHEATING AND FIRE.

Use complete wire without joining.

Use approved socket and plug with earth pin.

Wire connection in this area must follow to national wiring rules.

Do not joint wires

OR

OR OR

In case of indoor power supply In case of outdoor power supply

OR

OR OR

12.2.4.4 Cutting and flaring the piping

1 Please cut using pipe cutter and then remove the burrs.

2 Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused. Turn the piping end down to avoid the metal powder entering the pipe.

3 Please make flare after inserting the flare nut onto the copper pipes.