• No results found

General Data - Heat Pump (R22)

In document MCM 020D/DR MCM 025D/DR MCM 030D/DR (сторінка 41-46)

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.

General Data - Heat Pump (R22)

Btu/h W Btu/h

W W W A A V/Ph/Hz

W/W W/W

l/s / CFM l/s / CFM l/s / CFM EXTERNAL STATIC PRESSURE (H/M/L) mmAq

dBA mm/in mm/in mm/in mm/in mm/in mm/in kg/lb mm/in l/s / CFM

dBA mm/in mm/in mm/in mm/in mm/in mm/in kg/lb LIQUID mm/in

GAS mm/in

kg/lb

750 / 29.5 855 / 33.7

62 / 137

1.50 / 3.31 328 / 12.9 810 / 31.9 990 / 39.0 415 / 16.3

9.5 / 3/8 15.9 / 5/8 FLARE VALVE REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

2.67

R22 OUTDOOR CAP. TUBE

2.81 COP

6890 MLC 025CR

12.1 2574 24000 23500 MCM 025DR

54 / 53 / 50 245 / 520 297 / 630

0 274 / 580 220 - 240 / 1 / 50

11.7 2494 7030

214 / 8.4 1214 / 47.8

1311 / 51.6 670 / 26.3

760 / 29.9 301 / 11.9

43 / 95

UNIT WEIGHT

19.1 / 3/4

HEIGHT WIDTH DEPTH

755 / 1600 52

PIPE CONNECTION

TYPE SIZE

UNIT WEIGHT

CONDENSATE DRAIN SIZE

UNIT DIMENSION

PACKING DIMENSION

HEIGHT WIDTH DEPTH UNIT DIMENSION

SOUND PRESSURE LEVEL PACKING

DIMENSION

HEIGHT WIDTH DEPTH HEIGHT WIDTH DEPTH

AIR FLOW MODEL

OUTDOOR UNIT

LOW

INDOOR UNIT

CONTROL AIR DISCHARGE NOMINAL RUNNING CURRENT (COOLING) NOMINAL RUNNING CURRENT (HEATING) POWER SOURCE

NOMINAL COOLING CAPACITY

NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING) NOMINAL TOTAL INPUT POWER (HEATING)

EER

OUTDOOR UNIT

REFRIGERANT CHARGE

AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM) OPERATION WIRELESSS OR WIRED MICROCOMPUTER REMOTE CONTROL

INDOOR UNIT

SOUND PRESSURE LEVEL (H/M/L) AIR FLOW

HIGH MEDIUM

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

General Data - Heat Pump (R22)

MLC 028CR MLC 030CR

Btu/h 26500 30000 / <30000>

W 7770 8790 / <8790>

Btu/h 27000 32000 / <32000>

W 7910 9380 / <9380>

W 2894 2881 / <2861>

W 2674 2921 / <2901>

A 14.3 13.8 / <5.7>

A 13.6 14 / <5.9>

V/Ph/Hz

W/W 2.68 3.02 / <3.07>

W/W 2.96 3.21 / <3.23>

R22 R22

OUTDOOR CAP. TUBE OUTDOOR CAP. TUBE + TXV

l/s / CFM l/s / CFM l/s / CFM EXTERNAL STATIC PRESSURE (H/M/L) mmAq

dBA mm/in mm/in mm/in mm/in mm/in mm/in kg/lb mm/in

l/s / CFM 741 / 1570 1605 / 3400

dBA 54 58

mm/in 750 / 29.5 850 / 33.5

mm/in 855 / 33.7 1030 / 40.6

mm/in 328 / 12.9 400 / 15.8

mm/in 810 / 31.9 1000 / 39.4

mm/in 990 / 39.0 1200 / 47.2

mm/in 415 / 16.3 560 / 22.1

kg/lb 68 / 150 95 / 209

LIQUID mm/in 9.5 / 3/8 9.5 / 3/8

GAS mm/in 15.9 / 5/8 15.9 / 5/8

kg/lb 2.18 / 4.81 2.15 / 4.74

EER - 1Ø / <3Ø>

COP - 1Ø / <3Ø>

REFRIGERANT TYPE

REFRIGERANT CONTROL (EXPANSION DEVICE)

REFRIGERANT CHARGE

220 - 240 / 1 / 50 <380 - 415 / 3 / 50>

FLARE VALVE 670 / 26.3

249 / 9.8 0

AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM) WIRELESSS OR WIRED MICROCOMPUTER REMOTE CONTROL

1361 / 53.5 297 / 630 MCM 030DR

INDOOR UNIT

19.1 / 3/4 760 / 29.9 345 / 13.6 1214 / 47.8 51 / 50 / 48 255 / 540 326 / 690

45 / 99

UNIT WEIGHT UNIT WEIGHT

AIR FLOW

DEPTH CONDENSATE DRAIN SIZE

UNIT DIMENSION

HEIGHT WIDTH

UNIT DIMENSION WIDTH

PIPE CONNECTION

TYPE SIZE

DEPTH

PACKING DIMENSION

HEIGHT WIDTH DEPTH NOMINAL RUNNING CURRENT (COOLING) - 1Ø / <3Ø>

NOMINAL RUNNING CURRENT (HEATING) - 1Ø / <3Ø>

SOUND PRESSURE LEVEL PACKING DIMENSION

HEIGHT WIDTH DEPTH

OUTDOOR UNIT

POWER SOURCE - 1Ø / <3Ø>

HEIGHT MODEL

OUTDOOR UNIT

SOUND PRESSURE LEVEL (H/M/L) NOMINAL COOLING CAPACITY - 1Ø / <3Ø>

NOMINAL HEATING CAPACITY - 1Ø / <3Ø>

NOMINAL TOTAL INPUT POWER (COOLING) -1Ø / <3Ø>

NOMINAL TOTAL INPUT POWER (HEATING) - 1Ø / <3Ø>

INDOOR UNIT

MEDIUM LOW

CONTROL AIR DISCHARGE

OPERATION HIGH AIR FLOW

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

General Data - Heat Pump (R22)

MLC 035CR MLC 040CR

Btu/h 34000 39000 / <39000>

W 9960 11420 / <11420>

Btu/h 35000 41000 / <41000>

W 10260 12020 / <12020>

W 2980 3383 / <3353>

W 2980 3263 / <3233>

A 15.2 16.5 / <5.9>

A 15.2 15.9 / <5.3>

V/Ph/Hz

W/W 3.34 3.38 / <3.41>

W/W 3.44 3.68 / <3.72>

l/s / CFM l/s / CFM l/s / CFM EXTERNAL STATIC PRESSURE (H/M/L) mmAq

dBA mm/in mm/in mm/in mm/in mm/in mm/in kg/lb mm/in l/s / CFM

dBA mm/in mm/in mm/in mm/in mm/in mm/in

kg/lb 95 / 209 100 / 221

LIQUID mm/in

GAS mm/in

kg/lb 2.60 / 5.73 2.60 / 5.73

REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP. TUBE + TXV

OUTDOOR UNIT

REFRIGERANT CHARGE

AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM) OPERATION WIRELESSS OR WIRED MICROCOMPUTER REMOTE CONTROL

INDOOR UNIT

19.1 / 3/4 1200 / 47.2

560 / 22.1

FLARE VALVE 9.5 / 3/8 850 / 33.5 1030 / 40.6

400 / 15.8 1000 / 39.4

0 420 / 890

1605 / 3400 58 70 / 154 1816 / 71.4

670 / 26.3 249 / 9.8 MCM 040DR

R22

220 - 240 / 1 / 50 <380 - 415 / 3 / 50>

19.1 / 3/4 760 / 29.9 345 / 13.6 1714 / 67.4 54 / 53 / 52 368 / 780 477 / 1010

SOUND PRESSURE LEVEL (H/M/L) NOMINAL COOLING CAPACITY - 1Ø / <3Ø>

NOMINAL HEATING CAPACITY - 1Ø / <3Ø>

NOMINAL TOTAL INPUT POWER (COOLING) - 1Ø / <3Ø>

NOMINAL TOTAL INPUT POWER (HEATING) - 1Ø / <3Ø>

NOMINAL RUNNING CURRENT (COOLING) - 1Ø / <3Ø>

NOMINAL RUNNING CURRENT (HEATING) - 1Ø / <3Ø>

POWER SOURCE - 1Ø / <3Ø>

REFRIGERANT TYPE

AIR FLOW

LOW

INDOOR UNIT

CONTROL AIR DISCHARGE

HIGH MEDIUM MODEL

OUTDOOR UNIT

EER - 1Ø / <3Ø>

COP - 1Ø / <3Ø>

UNIT WEIGHT

CONDENSATE DRAIN SIZE

UNIT DIMENSION UNIT DIMENSION

SOUND PRESSURE LEVEL PACKING DIMENSION

HEIGHT WIDTH DEPTH HEIGHT WIDTH DEPTH

PACKING DIMENSION

HEIGHT WIDTH DEPTH HEIGHT WIDTH AIR FLOW

DEPTH UNIT WEIGHT

PIPE CONNECTION

TYPE SIZE

1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.

2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.

3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR

4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.

General Data - Heat Pump (R22)

MCM 050DR MCM 062CR

MLC 050CR MLC 061CR

Btu/h 48000 56000

W 14067 16410

Btu/h 48000 56000

W 14067 16410

W 4491 5593

W 4081 4551

A 8.3 9.4

A 6.2 8.1

V/Ph/Hz 380 - 415 / 3 / 50 380 - 415 / 3 / 50

W/W 3.13 2.93

W/W 3.45 3.61

R22 R22

OUTDOOR CAP. TUBE + TXV CAP. TUBE - INDOOR (COOLING) &

OUTDOOR (HEATING)

l/s / CFM 491 / 1040 731 / 1550

l/s / CFM 448 / 950 623 / 1320

l/s / CFM 387 / 820 472 / 1000

EXTERNAL STATIC PRESSURE (H/M/L) mmAq 0 0

dBA 54 / 53 / 52 56 / 53 / 46

mm/in 249 / 9.8 285 / 11.2

mm/in 1714 / 67.4 1903 / 74.9

mm/in 670 / 26.3 680 / 26.8

mm/in 345 / 13.6 368 / 14.5

mm/in 1816 / 71.4 1984 / 78.1

mm/in 760 / 29.9 760 / 29.9

kg/lb 70 / 154 85 / 187

mm/in 19.1 / 3/4 19.1 / 3/4

l/s / CFM 1605 / 3400 1793 / 3800

dBA 58 61

mm/in 850 / 33.5 850 / 33.5

mm/in 1030 / 40.6 1030 / 40.6

mm/in 400 / 15.8 460 / 18.1

mm/in 1000 / 39.4 1016 / 40.0

mm/in 1200 / 47.2 1178 / 46.4

mm/in 560 / 22.1 602 / 23.7

kg/lb 105 / 231.5 108 / 238.1

LIQUID mm/in 9.5 / 3/8 12.7 / 1/2

GAS mm/in 19.1 / 3/4 19.1 / 3/4

kg/lb 2.75 / 6.06 5.00 / 11.02

HEIGHT WIDTH DEPTH UNIT WEIGHT

FLARE VALVE SOUND PRESSURE LEVEL (H/M/L)

PIPE CONNECTION

TYPE SIZE

UNIT WEIGHT

CONDENSATE DRAIN SIZE

DEPTH

AUTOMATIC LOUVER (UP & DOWN) & MANUAL LOUVER (BOTTOM) OPERATION WIRELESSS OR WIRED MICROCOMPUTER REMOTE CONTROL

PACKING DIMENSION

HEIGHT WIDTH UNIT DIMENSION

UNIT DIMENSION

AIR FLOW

SOUND PRESSURE LEVEL MODEL

OUTDOOR UNIT

LOW

INDOOR UNIT

CONTROL AIR DISCHARGE NOMINAL COOLING CAPACITY

EER COP

REFRIGERANT CONTROL (EXPANSION DEVICE) NOMINAL HEATING CAPACITY

NOMINAL TOTAL INPUT POWER (COOLING) NOMINAL TOTAL INPUT POWER (HEATING)

INDOOR UNIT

HEIGHT WIDTH DEPTH PACKING

DIMENSION

HEIGHT WIDTH

OUTDOOR UNIT

REFRIGERANT CHARGE

NOMINAL RUNNING CURRENT (COOLING) NOMINAL RUNNING CURRENT (HEATING) POWER SOURCE

REFRIGERANT TYPE

AIR FLOW

HIGH MEDIUM

DEPTH

In document MCM 020D/DR MCM 025D/DR MCM 030D/DR (сторінка 41-46)